What should I do if the concrete pump leaks due to local leakage?

Your current location: Home >> News >> Company News

What should I do if the concrete pump leaks due to local leakage?

Date of release:2019-03-08 Author:Qingdao Konyle Group Co., Ltd. Click:

      The blockage and solution measures caused by local slurry leakage of concrete pump, due to the leakage of mortar, affect the quality of commercial concrete on the one hand, and on the other hand, the slump of commercial concrete will decrease and the pumping pressure of concrete will be caused. Loss, which leads to blockage. There are mainly the following reasons for leakage:

      (1) The pipe joint is not tightly sealed.

        The concrete transfer pump pipe joint is not tightly sealed, the pipe clamp is loose or the seal ring is damaged and the slurry is leaked. In this case, tighten the pipe clamp or replace the seal.

IMG_6705.jpg


     (2) The gap between the concrete pump glasses plate and the cutting ring is too large

        When the concrete pump glass plate and the cutting ring are severely worn, the gap between the two becomes large. When the clearance is too large, the gap between the glasses plate and the cutting ring must be reduced by adjusting the special-shaped bolts. If it cannot be adjusted, the worn parts should be replaced immediately. This method is only applicable to the “S” valve series commercial concrete pump.

      (3) Commodity concrete piston wear is serious

        Operators should always observe whether the water in the concrete pump tank is turbid, with or without mortar. Once the water is found to be turbid or there is mortar in the water, it indicates that the commercial concrete piston has worn out. At this time, the concrete pump piston should be replaced in time, otherwise the pipe will be blocked due to leakage and pressure loss, and the wear of the piston and the delivery cylinder will be aggravated.

IMG_6579.jpg


     (4) Leakage caused by severe wear of commercial concrete conveying cylinders

        If the water in the tank is quickly turbid after each replacement of the piston of the concrete pump, and the piston is good, it indicates that the tank is worn and the tank needs to be replaced.

        Konecra Group specializes in the manufacture of concrete pumping equipment for more than 20 years. The concrete equipment is of various types and high quality. The products are exported to more than 30 countries and regions such as Europe, Asia, Southeast Asia, South America, Africa and Oceania. Adhering to the "customer first principle", we are committed to providing customers with quality pre-sales, sales, and after-sales services, so that our concrete equipment will provide customers with an excellent construction experience. Strong production, management and service teams escort the customer's concrete equipment.

       Through the above introduction, I believe that everyone should block the pipe caused by the local leakage of the concrete pump. I have already understood, thank you for your attention to Qingdao Konele Group Co., Ltd. official website www.conele88.com.

 

IMG_6570.jpg



The address of this article:http://en.conele88.com/news/360.html

Key word:Concretepumpprice,Concretepumpmanufacturer,Concretepump,whichisgood?

Please leave a message for us
Please input the message here, and we will contact you as soon as possible.
name
Contacts
Telephone
Telephone
mailbox
mailbox
address
address